Knapsis A, Schelzig H and Oberhuber A
Knapsis A, Schelzig H and Oberhuber A*
Department of Vascular and Endovascular Surgery, University of Duesseldorf, Germany
Received Date: October 14, 2016; Accepted Date: October 17, 2016; Published Date: October 19, 2016
Citation: Knapsis A, Schelzig H, Oberhuber A. Visualization of an Aortic Coarctation, Induced by a Thoracic Stent Graft, Using 4D Magnetic Resonance Imaging. Ann Clin Lab Res. 2016, 4:4 doi: 10.21767/2386-5180.1000126
In 2001 a 13-year-old girl was taken to hospital after car accident, injured by multiple traumas, including an aortic rupture loco typico. Bleeding was brought under control via an endovascular approach with a Gore (W. L. Gore and Associates, Flagstaff, Ariz, USA) iliac limb 14-16-7. Follow-up CT scans showed over the years a relevant, but constant, bird-beak configuration of the stent graft. In 2009 the patient developed progressive arterial hypertension with a secondary hyperparathyroidism. For further investigation a conventional angiography with pressure gradient measurement and a four-dimensional magnetic resonance imaging was performed. The quantitative flow measurements were obtained by means of a retrospective ECG gated cardiacphase resolved three-dimensional T1 weighted fast gradient echo acquisition
In 2001 a 13-year-old girl was taken to hospital after car accident, injured by multiple traumas, including an aortic rupture loco typico. Bleeding was brought under control via an endovascular approach with a Gore (W. L. Gore and Associates, Flagstaff, Ariz, USA) iliac limb 14-16-7. Follow-up CT scans showed over the years a relevant, but constant, bird-beak configuration of the stent graft (Figure 1). In 2009 the patient developed progressive arterial hypertension with a secondary hyperparathyroidism. For further investigation a conventional angiography with pressure gradient measurement and a four-dimensional magnetic resonance imaging was performed. The quantitative flow measurements were obtained by means of a retrospective ECG gated cardiacphase resolved three-dimensional T1 weighted fast gradient echo acquisition [1,2].
The pressure gradient across the stent graft was 39 mmHg. Angiography showed a significant movement of the proximal end of the stent graft (Figure 2). The MRI confirmed the suspicion of a high-grade stenosis resulting in a functional coarctation. Flow analysis showed acceleration from 58 cm/s in the ascending aorta to 180 cm/s at the proximal end of the stent graft (Figure 3 and Video 1). The patient underwent open conversion with explantation of the stent graft and prosthetic graft insertion.
Video 1: HPLC chromatogram of the nine reference compounds in 50% aqueous methanol, measured at 370nm. Retention times for rutin, sutherlandin A, sutherlandin B, kaempferol-3-O-rutinoside, sutherlandin C, sutherlandin D, quercitrin, quercetin and kaempferol were 11.9, 12.7, 13.8, 15.3, 16.2, 17.0, 18.0, 26.2 and 28.1 minutes, respectively.
This work was supported by a grant from Gore (W. L. Gore and Associates, Flagstaff, Ariz, USA) and Medtronic (Medtronic World Medical, Sunrise, Fl, USA).
